MIP KOD | |
ÜRÜN ADI | G2 AUTO CPAP Device |
MARKA | Respirox |
MODEL |
Reslex - Expiration Comfort Respirox CPAP also offers exclusive reslex technology, which provides better breathing comfort for the patient, reducing pressure on the outside and allowing the patient to spend less effort during sleep.
Dimension: 22cm * 19,4cm * 11,2cm
Weight: 2.0 kg.
Power requirement: 230 VAC, 50 Hz
Reslex: 3 step
Pressure range: 4-20 cmH2 °
Heater humidifier: (optional)
Noise level: 24dBA
365 days to record data
Ramp time: 0-60 minutes
Automatic altitude setting: 4 stages
Auto On / Off
Treatment counter
Automatic air leak compensation
Detailed data recording
ICode feature
Usage hour report
Alarm: Power failure, mask and hose leak alarm
Approved by Ministry of Health CE and ISO Certified
MIP KOD | |
ÜRÜN ADI | G2 AUTO BPAP Device |
MARKA | Respirox |
MODEL |
PRODUCT FEATURES
Reslex - Expiration Comfort Respirox CPAP also offers exclusive reslex technology, which provides better breathing comfort for the patient, reducing pressure on the outside and allowing the patient to spend less effort during sleep.
Dimension: 22cm * 19,4cm * 11,2cm
Weight: 2.0 kg.
Power requirement: 230 VAC, 50 Hz
Reslex: 3 step
Pressure range: 4-20 cmH2 °
Heater humidifier: (optional)
Noise level: 24dBA
365 days to record data
Ramp time: 0-60 minutes
Automatic altitude setting: 4 stages
Auto On / Off
Treatment counter
Automatic air leak compensation
Detailed data recording
ICode feature
Usage hour report
Alarm: Power failure, mask and hose leak alarm
Approved by Ministry of Health CE and ISO Certified
MIP KOD | |
ÜRÜN ADI | Airfit N20 Nose Mask |
MARKA | Resmed |
MODEL |
Whatever the sleeping position, it moves freely throughout the night.
InfinitySeal ™ with cushioning technology, yet the most compatible
Ideal for breathing in the nose during sleep.
Excellent comfort and performance
What does a perfect CPAP mask do? Comfort and performance are perhaps two key factors. The AirFit N20 features the most adaptive InfinitySeal ™ mindset we have designed with a soft, flexible frame with integrated cushioning.
We are committed to making the most personalized mask possible. For this reason, we proudly present our AirFit N20 mask for stylish lavender axles and versions with a smaller size range.
Using Your AirFit N20;
MIP KOD | |
ÜRÜN ADI | CPAP Hose 22 mm |
MARKA | BMC |
MODEL |
BMC CPAP Masking Breathing Air Silicone Hose Length 183 cm connect Massager Machine Accessories Oxygen Pipe
MIP KOD | |
ÜRÜN ADI | Medicraft Auto Cpap |
MARKA | Others |
MODEL |
LIVE TITRATION WIRELESS
Medicraft-specific titration program, sleep events can be observed in real time with detailed graphics. Thus, the most accurate therapy pressure and device model for the patient is determined.
3 CHANNEL ALGORITHM
AutoCPAP 3 channel algorithm; detects apnea, hypopnea, snoring events. Thanks to its advanced software, the patient is monitored throughout the treatment and the required pressure level is applied automatically.
AUTOCPAP FLEXIBILITY FEATURE3
stage flexibility feature reduces therapy pressure in the range of 1-3 mbar during expiration and provides a therapy suitable for patients' natural breathing. This feature is one of the most important factors that increase patients' comfort and adaptation to therapy.
Standard Features
Digital PID pressure controlled operation Three channel Autocpap algorithm (Apnea - Snoring - Upper Respiratory Resistance) Medicraft Autocpap working method Precise snore detection thanks to digital filter applied with high speed sampling Maximum, minimum and initial pressure setting 4-20 mbar operating range 4GB SD Card Flexibility feature Turkish menu Smart 4 key system Wide graphic LCD screen Auto accessory detection system Ramp feature Mask test Clinic menu lock Auto start-stop Display light adjustment Free software
Optional Accessories
Heater humidifier (5 steps) Li-Ion battery (8 hours) Cigarette lighter adapterWireless communication kit
MIP KOD | |
ÜRÜN ADI | Airsep Freestyle Comfort Portable Oxygen Concentrator |
MARKA | AirSep |
MODEL |
AirSep FreeStyle comfort; It is a portable oxygen concentrator that can offer 5 different PulseDose settings. It provides oxygen support of approximately 95% purity to patients who want to move freely. It has a wide treatment capacity thanks to the PulseDose system with its 1-5 setting options. Users in need of oxygen (COPD, idiopathic pulmonary fibrosis, cystic fibrosis, etc.) can enjoy an active life thanks to the light and reliable AirSep FreeStyle 5.
Thanks to the UltraSense technology found only in the AirSep FreeStyle 5 portable oxygen concentrator, it detects the user's breathing more precisely than many portable devices. Thanks to UltraSense, oxygen is delivered to the user in a short time like milliseconds. In this way, more efficient oxygen therapy is provided. Thanks to its smart microprocessor, it provides fast and reliable oxygen support even in sleep mode. Thanks to its powerful compressor, the FreeStyle 5 portable oxygen concentrator can even be used with cannulas up to 7.62 meters long.
The new plug-in battery can serve over 4 hours in the 1st PulseDose setting. In this way, people who need oxygen support can now comfortably attend a music festival or go shopping.
Since FreeStyle is an FAA approved device, it can be used safely on airplanes. (Check with your airline for flight details)
Technicial Specifications
Settings: 1 to 5 PulseDose flow O2 Concentration: 90% O2 +5.5% / -3%
Dimensions: 27.2 cm H x 16.8 cm W x 11.2 cm
Weight: 3kg
Electricity Consumption: AC Power: 100 – 240 VAC, 50/60 Hz
DC Power: 12 – 24 VDC
Battery Duration: Setting 1 – 4.25 hours
Setting 2 – 2.5 hours
Setting 3 – 2 hours
Setting 4 – 1.75 hours
Setting 5 – 1.25 hours
Charging Time: 4-5 hours
With Second Battery: Setting 1 – 8.5 hours
Setting 2 – 5 hours
Setting 3 – 4 hours
Setting 4 – 3.5 hours
Setting 5 – 2.5 hours
Audible Alarm: Start, PulseDose, battery level, cannula, system
Visual Warning: General fault
Working Temperature: Between +5 C and +40 C
Storage Temperature: -20 C to +60 C
Operating Altitude: Up to 3,657 meters
Place of Manufacture: USA
Based on 14.7 psi (101 kPa) atmospheric pressure at 21°C (70°F)
Operating outside of these conditions of use does not meet Oxygen Condensation conditions at higher liter flow rates of the condenser
may limit his ability. The warm-up screen will continue to appear until the concentrator reaches the target density, or for a maximum of 15 minutes.
can. Continue to use the unit during this time.
The anticipated useful life is at least five years. The expected shelf life of the sieve beds is approx.
for one year.
AirSense 10 Elite Supplier. To navigate through non-complicated settings and menus, just start and press the button to go hunting. The integration of this device in the HumidAir ™ (Humidifier), a more comfortable experience and convenient temperature and humidity retention tube automatically work.
A comfortable start! (AutoRamp) If you have a sleeping problem, go for them with low pressure cushioning too. AutoRamp starts with low pressure for more comfortable sleep.
Built-in ambient light sensor !! The light level of the screen is based on the brightness of the environment. Bring your keyframe to the screen. The screen light shuts off at night so as not to disturb the more comfortable sleep.
Other Features
The Easy-Breathe engine is quieter than you and your partner whisper, offering more peaceful night's sleep.
The simple and intuitive user interface provides feedback on morning treatment and it is much easier to change settings.
User-friendly controls make it easier for you to navigate and customize the menus with the color LCD display.
The SmartStart ™ function initiates the therapy with breathing into the size mask as soon as possible. If you just remove the dick, stop in a few seconds.
Integrated HumidAir ™ humidifier with Climate Control technology and optional ClimateLine (thin hose) Long lasting humidification with air heated tube.
How to use?
Here are some tips on setting up the site;
The therapy system most likely consists of a mask, a tube, a therapy device, and a moisturizer. Translate for all sections. Knowing how to set up equipment and equipment does not make you different for your treatment!
SOME TIPS IN RESMED:
First, make sure you place it on a specific surface. Do not put your business into luck.
When you sleep in your bed, put it in a place where you can reach the auditors.
If the device is empty, someone does not cover it with the cover, keep it away from materials such as walls, heaters.
ResMed S9 Escape is the award-winning S9 standard CPAP platform model. User-friendly features and a host of advanced technologies are designed to help ease the transition. So you can get long-term benefits with a restful sleep. With elegant lines and compact size, the S9 Escape design looks natural on the bed, like a clock radio. It is an elegant comfort device away from the pessimistic air that the medical devices reflect to the subconscious.
Key Features
With the Easy-Breathe motor feature (and your partner's) sleeping environment is quieter and quiet.
Optional H5i ™ Climate Controlled Heated Humidifier provides an ideal humidification and temperature setting for real-time environment. Thus, dry throat and mouth side effects are most reduced or protected. The synchronized heater will provide complete protection from condensation.
Easy-Breathe technology will give you a really comfortable breathing experience. Natural inhalation and exhalation patterns are monitored by the device.
User-friendly controls, intuitive interface and bright color LCD guide you through the setup process and make it easy to navigate menus and customize settings.
Slim design makes your movements easier on your trips.
Reslex - Expansion Comfort
Respirox CPAP also offers exclusive reslex technology, which allows the patient to have better respiratory comfort, reducing pressure on the outside, and allowing the patient to spend less effort during sleep.
Reslex Feature
It is the ability to throw excess pressure out of the patient without exposing the patient during expiration, minimizing effort. This feature minimizes the causes of heart rhythm disturbances in patients. The goal is to get the rest of the day away from the pressure of the patient, while allowing the patient to have a comfortable night's sleep. In order to activate Reslex feature, user login must be done from the menu.
iCode Feature
The ability to save users' data. The Respirox CPAP device records data for 365 days. is an advanced technology that allows patients to see the time they have used before and the AHI (apnea, hypopnea) indices.
* The length of time the patient has used
* Device, mask, patient compliance
* AHI (apnea hypopnea) indices
* Average pressure
* Mask escapes
It keeps the user visible and keeps it in memory for 365 days. When the data storage is full, it saves the last day and deletes the day that it was first used, so you can see your current data whenever you want.
Auto User Features
* Respirox devices are equipped with a breathing sensor, without any trouble to press any key before the auto-opening feature of the device by removing the mask and auto-off feature is enabled. this feature can be activated and disabled from the menu.
* In heavy mask leakage, the device switches to alarm position and warns the user.
* Automatically adjusts the altitude level of the area you are in.
* If the power is turned off while the device is in operation, an automatic alarm is activated and warns the user.
Heater Humidifier Features
Respirox devices can optionally be integrated in the heater humidifier to adjust the temperature setting of the incoming air to the user in 5 steps.
With a lid guard designed to prevent water from escaping into your device, it allows you to use your device comfortably during the night. With a heating feature between 1-5, it allows the patient to have a comfortable night's sleep without being exposed to cold weather during sleep.
Smart Phone Application
To download free software (3B / BMC iCode) for Respirox devices, you can view your data anywhere and anytime using your iPhone and Android devices, iTunes and GooglePlay.
TECHNICAL SPECIFICATIONS :
Dimension: 22cm * 19,4cm * 11,2cm
Weight: 2.0 kg
Power requirement: 230 VAC, 50 Hz
Reslex: 3 step
Pressure range: 4-20 cmH2 °
Heater humidifier: (optional)
Noise level: 24dBA
365 days to record data
Ramp time: 0-60 minutes
Automatic altitude setting: 4 stages
Auto On / Off
Treatment counter
Automatic air leak compensation
Detailed data recording
iCode feature
Usage hour report
Alarm: Power failure, mask and hose leak alarm
Approved by Ministry of Health CE and ISO Certified
Respirox Auto AUTO CPAP Device Automatic Pressure Setting Technology and Sensitivity Setting Reslex feature iCode Remote Advanced Data Recording Data Recording 365 days Auto Swich feature (auto on / off) Auto Altitude setting Alarm feature Emergency warning 5 stage Integrated heater humidifier For easy transportation holding line Min - Max 4 cmH2O / 20 cm H2O pressure range
Reslex Feature
It is the ability to throw excess pressure out of the patient without exposing the patient during expiration, minimizing effort. This feature minimizes the causes of heart rhythm disturbances in patients. The goal is to get the rest of the day away from the pressure of the patient, while allowing the patient to have a comfortable night's sleep. In order to activate Reslex feature, user login must be done from the menu.
iCode Feature
The ability to save users' data. The Respirox CPAP device records data for 365 days. is an advanced technology that allows patients to see the time they have used before and the AHI (apnea, hypopnea) indices.
* The length of time the patient has used
* Device, mask, patient compliance
* AHI (apnea hypopnea) indices
* Average pressure
* Mask escapes
It keeps the user visible and keeps it in memory for 365 days. When the data storage is full, it saves the last day and deletes the day that it was first used, so you can see your current data whenever you want.
Auto User Features
* Respirox devices are equipped with a breathing sensor, without any trouble to press any key before the auto-opening feature of the device by removing the mask and auto-off feature is enabled. this feature can be activated and disabled from the menu.
* In heavy mask leakage, the device switches to alarm position and warns the user.
* Automatically adjusts the altitude level of the area you are in.
* If the power is turned off while the device is in operation, an automatic alarm is activated and warns the user.
Heater Humidifier Features
Respirox devices can optionally be integrated in the heater humidifier to adjust the temperature setting of the incoming air to the user in 5 steps.
With a lid guard designed to prevent water from escaping into your device, it allows you to use your device comfortably during the night. With a heating feature between 1-5, it allows the patient to have a comfortable night's sleep without being exposed to cold weather during sleep.
Smart Phone Application
To download free software (3B / BMC iCode) for Respirox devices, you can view your data anywhere and anytime using your iPhone and Android devices, iTunes and GooglePlay.
TECHNICIAL SPECIFICATIONS :
Dimension: 22cm * 19,4cm * 11,2cm
Weight: 2.0 kg
Power requirement: 230 VAC, 50 Hz
Reslex: 3 step
Pressure range: 4-20 cmH2O
Heater humidifier: (optional)
Noise level: 24dBA
365 days to record data
Ramp time: 0-60 minutes
Automatic altitude setting: 4 stages
Auto On / Off
Treatment counter
Automatic air leak compensation
Detailed data recording
iCode feature
Usage hour report
Alarm: Power failure, mask and hose leak alarm
Approved by Ministry of Health CE and ISO Certified
AirSense 10 AutoSet is a self-regulating pressure therapy device that automatically adjusts pressure levels to suit your needs and to ensure you get the lowest pressure you need. When AirSense 10 AutoSet ResMed is used with the new Humidair heated humidifier and the ClimateLineAir heated tube, it offers the most comfortable temperature and humidity levels.
Key Features
Intelligent detection: With sleep-on detection AutoRamp starts by offering low pressure for extra comfort and after sleeping, gradually boosts pressure to the predicted level.
Just press the start key and get ready!
Simple and intuitive user interface provides feedback about treatment every morning. It is now easy for you to change the comfort settings with this interface.
Other Features
Built-in ambient light sensor; The light level of the display is automatically adjusted according to the brightness of the room. If you need to get up all night, the back of the screen will not spoil your partner and your comfort.
The Easy-Breathe engine provides you and your partner with a more peaceful night's sleep.
When the SmartStart function is masked, sleep apnea therapy begins with breathing. If you remove the dock, the unit automatically stops after a few seconds.
Increased comfort and consistent dampening throughout the night with the integrated Humidair ™ humidifier. Climate Control technology provides ultimate comfort, controlled heated tubing, and optional ClimateLineAir provides complete comfort.
How to use?
Here are some tips on setting up equipment; The therapy system most likely consists of a mask, a tube, a therapy device, and a moisturizer. You only need to navigate the therapy menu to set all the parts to detect. Having information about all equipment for your treatment and making the adjustments correctly will make your treatment much easier.
Here are some tips from ResMed:
First, make sure that you place the device on a stable, flat surface without covering it over. Do not put your business into luck.
Put your device in an accessible position for inspections when lying in your bed.
Do not cover the device with any blank, keep it away from materials such as walls, heaters, etc.
PERFORMANCE CHARACTERISTICS RESPIROX BiPAP S DEVICE
Automatic Pressure Setting and Sensitivity Setting
Reslex feature (Pressure Reduction)
ICode Remote Advanced Data recording
Data recording 365 days
Auto Swich feature (auto on / off)
Auto Altitude setting
Alarm feature
Air leak warning
5 stage Integrated heating humidifier Handle for easy handling
EPAP - IPAP Working between 4 cm HO2 / 30 cm HO2
Four modes: CPAP, Spontaneous (S).
AUTOMATIC PRESSURE ADJUSTMENT AND SENSITIVITY ADJUSTMENT FEATURES
Pressure adjustment depending on the position of the bed, measuring the most appropriate pressure to the patient.
Instant response to precise pressure changes with a pressure range of 0.5 - 1.
The sensitivity can be adjusted according to the needs of the patient between 1-5 so that they can breathe without giving the patient with a smooth usage.
RESLEX FEATURE
It is the ability to throw out excess pressure by expending a minimum effort without exposing the patient during expiration. The goal is to get the rest of the day away from the pressure of the patient, while allowing the patient to have a comfortable night's sleep. To enable the Reslex feature, a menu entry must be made.
iCODE FEATURE
The ability to save users' data. Respirox Bpap ST records data for 365 days. It is a sophisticated technology that allows patients to see the time they have used before and the AHI (apnea, hypopnea) indices.
* The length of time the patient has used
* Device, mask, patient compliance
* AHI (apnea hypopnea) indices
* Average pressure
* Mask escapes
It keeps the user visible and keeps it in memory for 365 days. When the storage is full, it saves the last day and deletes the day it was first used, so you can see your current data every time you want.
AUTOMATIC USER FEATURES
* Respirox devices are equipped with a breathing sensor, without any trouble to press any key before the auto-opening feature of the device by removing the mask and auto-off feature is enabled. This feature can be activated and disabled from the menu.
* In heavy mask leakage, the device switches to alarm position and warns the user.
* Automatically adjusts the altitude level of the area you are in.
* If the power is turned off while the device is in operation, an automatic alarm is activated and warns the user.
HEATER HUMIDIFIER FEATURES
Respirox devices can optionally be integrated in the heater humidifier to adjust the temperature setting of the incoming air to the user in 5 steps.
It is designed to prevent water from escaping into the device, allowing you to use your device easily during the night.
With a heating stage of 1-5, the patient can get a comfortable night's sleep without exposure to cold weather during sleep.
For more information about iCode functions, you can view the Respirox iCode Quick Reference Form.
SMART TELEPHONE APPLICATIONS
To download free software (3B / BMC iCode) for Respirox devices, you can view your data anywhere and anytime using your iPhone and Android devices, iTunes and GooglePlay.
TECHNICIAL SPECIFICATIONS :
• Respiration rate (Res. Rate)
• Measure: 22cm * 19,4cm * 11,2cm
• Weight: 2,0 kg
• Power requirement: 230 VAC, 50 Hz
• Reslex: 3 step
• Pressure range: 4-30 cmH2 °
• Heated humidifier: (Optional)
• Noise level: 24 dBA
• Can record 365 days of data
• Ramp Time: 0-60 minutes
• Automatic altitude setting: 4-stage
• Auto On / Off
• Treatment counter
• Automatic air leak compensation
• Detailed data recording
• iCode feature
• Usage hour report
• Alarm: Power failure, mask and hose leakage alarm
• Adjustable trigger and speed indicator
Respirox offers exclusive reslex technology, which provides better breathing comfort for the patient, reduces pressure on the outside, and allows the patient to make less effort during sleep. Reslex Feature It is the ability to throw out excess pressure by exposing the patient to minimal expulsion during expiration. This feature minimizes the causes of heart rhythm disturbances in patients. The goal is to get the rest of the day away from the pressure of the patient, while allowing the patient to have a comfortable night's sleep. In order to activate Reslex feature, user login must be done from the menu.
The patient should have spontaneous breathing, but the breathing frequency should be adjustable by the device. The BPAP ST should be tried in cases where BPAP does not enter the respiratory tract, treatment is required at higher pressure, and especially in the presence of central apneas. In patients with obstructive sleep apnea syndrome as well as pathologies leading to alveolar hypoventilation such as restrictive pulmonary disease, COPD, obesity-hypoventilation syndrome, sleep-related hypoventilation / hypoxemic syndrome, it may be advisable to use spontaneous respiration and determination that the triggering power is insufficient.
The CSA detection feature differentiates between obstructive and central apneas so you can be confident that your patient is receiving appropriate therapy and pressure.
Detailed data options allow you to monitor therapy progress to ensure any issues are detected and addressed early, helping you deliver quality patient care.
Easy-Breathe technology delivers air in a smooth waveform that intelligently follows the patient's natural breathing pattern, helping to provide a more comfortable therapy experience.
The Easy-Breathe motor allows for a peaceful environment for the patient and bed partner.
The sleep test is used to assess sleep apnea findings and to diagnose sleep disorders. Sleep apnea is a sleep disorder characterized by a period of time during which the breathing stops for a while and continues again. Symptoms of sleep apnea;
The sleep test is also used to diagnose other sleep disorders.
The national heart, lung and blood institute warns that untreated sleep disorders increase the risk of heart attack, high blood pressure and stroke.
USA MADE Up to 6 hours to 6 hours. ONLY 3 KG Model: PM4150 Weight: 3kg Oxygen Throw: 1-5LPM Usage Time: 6-8 hours Height: 5.7 cm Width: 16,5 cm Depth: 11,4 cm Operating Temperature: 5 ° C to 40 ° C Mode of Study: Sensitive to breathing. Car Charger Kit: Yes. |
Oxygen Minute Volume Setting 1: 240 ml / min Setting 2: 380 ml / min Setting 3: 520 ml / min Setting 4: 660 ml / min Setting 5: 780 ml / min |
Approximate Battery Time (2 Batteries) Setting 1: 9 hours Setting 2: 6.4 hours Setting 3: 5 hours Setting 4: 3.6 hours Setting 5: 3 hours |
Oxygen concentrators decompose oxygen from gases in the air to provide patients with high concentrations of oxygen gas. These devices are commonly used in patients' homes. Light and portable models are also available for mobile use. The portable oxygen concentrator produced in order to ensure better quality of life for patients is the Inogen One G3 battery and is easy to use. It provides high intensity oxygen output. The Inogen One G3 portable oxygen concentrator can be used at home, at work, in a vehicle or in different locations without the need for electricity. The LCD shows the remaining battery time in hours and minutes. This allows the user to know when to charge the device.
The Inogen One G3 portable oxygen concentrator determines the onset of breathing and gives the user the right time and amount of oxygen while breathing. The device detects every breath received and works synchronously with the user. There are audible and visual alarms on the device. For example, when the person is not breathing or the cannula is disconnected, the device detects and emits an audible alarm. Thus it warns user in critical situations. This gives confidence to the patient and their relatives.
The Inogen One G3 portable oxygen concentrator is available 24 hours a day. Thanks to the car cigarette lighter kit, it works even without traveling.
Place of production: America
Warranty period: 3 years
Weight: 2.2 kg
Pulse dose: 4 levels
Working time with battery: 9 hours
Can work 24 hours a day
Sound level: 42 dBA
Sleep apnea is one of the most important diseases caused by snoring and can be expressed as a sleep breathing sleep. The sleep apnea, which means that the breathing stops and becomes superficial during sleep, can be repeated many times during the night. During the sleep apnea, relaxation occurs in the muscles that allow the upper respiratory tract to remain open. It is called sleep apnea for at least 10 seconds of breathing as a result of airway obstruction of tongue root or soft wrist or overgrown tonsils.
During the sleep apnea, the breathing effort continues, but after a while more and more this effort stimulates the brain and airway opens. The person who snores until the breath stops stops breathing again and again with a loud groan.
When necessary precautions are not taken, it is known that the sleep apnea increases the risk of traffic accidents 7-8 times by causing carelessness and causes job accidents. Although the incidence of sleep apnea is 1-4%, it can be better understood how serious a problem is if it is thought that 3% of diabetes mellitus and about 5% of asthma frequency.
Sleep apnea test is the most important step in the process of diagnosis and treatment of the disease. A sleep apnea test called "polysomnography" is a test that records brain activity and respiratory events throughout the night.
Polysomnography, a sleep apnea test, is based on the measurement of brain waves during sleep, eye movements, airflow in the mouth and mouth, snoring, heart rate, leg movements and oxygen levels. Patients need to stay in a sleeping room overnight in order to be able to do the sleep apnea test. During the test, the signals received by the cables connected to the various points of the body are transferred to the computer outside the room. By examining these records taken until the Sabah, many parameters such as how many times breathing stops during sleep, how long it stops, how long it takes to stop breathing, how oxygen values and heart rate are affected, and whether or not the patient suffers deep sleep.
The respiratory device, also called the ventilator, is used in the treatment of chronic respiratory insufficiency. Long-term mechanical ventilation at home is very important in the treatment of respiratory insufficiency. Breathing apparatus is widely used, especially in terms of chest wall and neuromuscular diseases. Two types of respiratory support are given to the patient through the ventilator used in ALS patients.
Non-invasive mechanical ventilation: Use of a respiratory support device only with the aid of a mask without opening the hole in the patient's respiratory tract
Invasive mechanical ventilation: The use of a breathing apparatus that will provide respiratory support by opening a hole in the respiratory tract, ie tracheostomy, by means of a cannula placed in the hole
Determination of home-type invasive mechanical ventilation device
The MV parameters for the patient's respiratory system must be determined
The power source of the breathing apparatus should be explained.
The desired alarm and warning systems in the respiratory device should be determined and the alarm limits should be set in the most appropriate way. In other words, systems such as power cut, oxygen deficiency, high pressure, battery power, charge level should be in the desired form if the patient leaves the device.
A spare ventilator should be provided with the breathing apparatus and it should be possible to use the spare breathing apparatus as soon as the problem is solved.
Patients should be tested for at least 48 hours with this respiratory device in the hospital or intensive care unit, as the type and parameters of the respiratory device that will be appropriate for the patient are determined by a specialist neurologist or chest physician in this area.
In this process, it is possible for the device to be suitable for the patient and for the patient to adapt to the device. Although the parameters detected in patients are applied, sometimes problems may arise in different respiratory devices. For this reason, more than one breathing apparatus may need to be tested. In cases where respiratory support at home is to be applied, the family doctor and the nurse who follows the patient can make a more successful application.
Cpap and BiPAP are respiratory devices used in patients with respiratory problems.
BIPAP (Bilevel positive airway pressure)
Continuous positive airway pressure (CPAP)
These two devices are used for external breathing assistance. Respiratory devices can be used not only for ALS, but also for many respiratory problems such as chronic lung disease, sleep apnea. Here, the target is to provide mechanical respiratory support for patients who can not get enough oxygen due to respiration. For ALS patients, a respiratory device, usually of the BIPAP type, is used. This is caused by the fact that these patients lose their ability to breathe spontaneously, especially in the night. The BIPAP breathing apparatus automatically switches on in this case, providing the patient with breathing needs. By responding to the respiratory reflex, they help the patient. These features are referred to as BIPAP S / T devices. They have an automatic respiratory system.
Artificial respiration ie mechanical ventilation can be done in 2 ways;
Non-invasive ie masked
Invasive, that is, breathing is made with a larynx attached to the tube. This is done by opening a hole in the patient's throat with a small surgical procedure.
A specialist doctor can decide which method will be applied to the patients. If there is a delegation report, respiratory devices may be covered by the social security institution. However, after the treatment, the devices must be returned to the institution.
The most common symptom in this group of diseases is Sleep Respiratory Disease (Obstructive Sleep Apnea Syndrome). The most common symptom is snoring. Snoring occurs during sleep with noisy breathing. This is due to the narrowing of the throat during sleep, which disturbs those who share the same bed with the person who snores according to their degree of discomfort, those who stay in the same house, even the neighbors. Excessive weight, alcohol intake, fatigue and insomnia also increase snoring, except for the causes of narrowness in the throat such as tonsils, small tongue and palate. Although it does not cause any problem for the person who snores, the partner who hears the snoring frequently and can not sleep comfortably for this reason comes in front of the family doctor, friend's warning doctor. Research has shown that snoring increases with age, middle age and nearly half of the population snore. When the narrowing of the throat, which plays a role in the snore, becomes more apparent, it leads to the complete closure of the airway, the cutting of the breath (apnea). It is called obstructive sleep apnea syndrome (sleep obstructive sleep apnea syndrome), which is frequently repeated during sleep, when breathing between noisy snoring, and therefore snoring, lasts for a long time (over 10 seconds) and then continues again with breathing and noisy snoring.
Sleep Respiratory Disease (Obstructive Sleep Apnea Syndrome)
Recurrent respiratory disorders (apnea, apnea, hypopnea: hypopnea) develop as a result of obstruction of the throat during sleep.
It causes sleep interruption due to the complete interruption of breathing or a considerable decrease in sleep during sleep, and causes a decrease in the proportion of oxygen in the body. Breathing ends with waking, breathing starts again. When alertness occurs in the nervous system, the effect of the relevant nervous system on the heart and vessels causes the blood pressure to rise. Degradation of sleep affects metabolism and sexual functions. Obstructive sleep apnea syndrome is therefore an important health problem that affects many body systems.
Patients often disgrace in a noisy way, have not received their morning sleep, wake up unrestrained. With the cause of insomnia, disturbances in mental ability and sleepiness during the day can develop.
Excessive weight, causes in the throat tightness, alcohol intake in the evening, some drugs aggravate respiratory arrest in sleep. The use of non-prescription medicines can be detrimental to the use of medicines related to sleep without knowing the underlying problem.
Obstructive sleep apnea syndrome is diagnosed in the sleep laboratory for sleep and respiratory changes. It is also necessary to work in sleep laboratories to regulate treatment in patients who will undergo pressure therapy
The prospect of community health can be summarized in three main sections:
Sleep disordered breathing is a common condition in the community: The most common cause of excessive sleepiness is known as sleep apnea syndrome (obstructive sleep apnea syndrome). It has been shown in studies that obstructive sleep apnea syndrome is present in 4% of men and 2% of women in adulthood. Up to 3% of cases have been reported in studies conducted in children. However, very few of the patients are diagnosed. It is estimated that only 1/10 of the patients can be diagnosed in USA where sleep laboratories are common.
Obstructive sleep apnea syndrome leads to major health problems (illness and death). Clinical consequences such as sleep disturbance, decreased oxygen, increased hypertension in patients with sympathetic nervous system hypertension, respiratory and cardiac insufficiency, stroke, impaired cardiac rhythm, and overweight (obesity) may develop. Insomnia can lead to accidents in people who use vehicles that require careful attention. Patients' compliance with their surroundings may deteriorate, job performance and quality of life may decrease. Studies have shown that the life expectancy of patients with obstructive sleep apnea hypopnea syndrome is reduced compared to the non-ill persons due to the mentioned disease outcomes and the expectation of life expectancy by treatment can be increased. Increased cardiovascular disease in these patients may result in fatal outcomes. This suggests the importance of obstructive sleep apnea syndrome in terms of community health.
Obstructive sleep apnea syndrome is a treatable disease. In obstructive sleep apnea syndrome, efficacy has been shown for today, it is a pressure therapy applied through mask in the form of treatment. The purpose of the treatment is to keep the upper airway, which has increased tendency to close during sleep, by giving positive pressure from the outside. Surgical treatment may be appropriate for patients with moderate disease who are not overweight and have anatomic stenosis in the upper airway. The other treatment that can be selected in these patients is oral devices (oral appliance). It can be said that treatment can reduce or eliminate the negative consequences of obstructive sleep apnea syndrome.
In summary, obstructive sleep apnea is an important public health problem threatening the quality and duration of the hypopnea syndrome. It needs to be recognized and treated appropriately in terms of patient and community health. Diagnosis and treatment are possible when referring to health centers, sleep laboratories related to the subject.
People with sleep apnea stop breathing during sleep. This can wake up dozens or even hundreds of times during the night. The duration of breathing may be as short as 10 seconds. Most patients do not remember waking up. A sleep test is needed to diagnose sleep apnea. Sleep-related breathing problems are most commonly seen in men, in overweight people, and in older adults. People with sleep apnea often benefit from treatment called positive airway pressure. This treatment keeps the airway open by providing air pressure through a mask attached to the nose during sleep.
In order to understand the dyspnea, it is necessary to know how a normal breathing is.
Breathing continues automatically.
Breathing and breathing can seem very simple but are autonomously managed by the brain and spinal cord.
Upper and lower respiratory tract
The respiratory system consists of two parts: the upper and lower airways.
Upper respiratory tract consists of nose, mouth, pharynx and larynx.
Lower respiratory tract; trachea, bronchi, alveoli and lung.
Respiratory Process
What starts breathing is in fact the effort to do to draw air into your body.
It cleans, warms and moistens the air entering the nose. The air then flows through the lungs to the trachea, bronchi and alveoli.
As you breathe, the chest extends and extinguishes.
Abnormal Respiration
Although respiration is the activity we do most often, it has a complex structure. Problems that can occur can affect the whole body in a negative way and cause problems.
There are three main types of sleep apnea:
Obstructive Sleep Apnea (OSA)
Central Sleep Apnea (CSA)
Mixed sleep apnea
Obstructive Sleep Apnea (OSA)
Obstructive Sleep Apnea is the most common type of sleep apnea. The diagnosis of sleep apnea is 84%.
Obstructive sleep apnea; It is in the upper respiratory tract and is caused by a blockage in the nose and throat that stops air flow to the lungs.
Why the upper respiratory tract may be blocked:
During sleep, the muscles relax and the airway stops and the airway stops.
Airway constriction thickness around neck.
Inflammatory tonsils or other transient causes.
Structural causes such as nose, neck, or chin.
Central Sleep Apnea (CSA)
Rare Central Sleep Apnea (CSA) may arise from some medications used in pain treatment such as opioids, heart failure, severe injuries and operations. And also;
Stroke
Glioma
Viral brain infection
It may occur in chronic respiratory disorders.
Although Central Respiratory Apnea is open in the Central Sleep Apnea, as a result of the absence of breathing effort, it is the breathing of the lungs that can not reach the air.
Central Sleep Apnea is usually confused with snoring and it is therefore difficult to notice.
Investigations 4 Patients with Central Sleep Apnea were found to have heart failure.
CSA is also associated with Cheyne-Stokes Respiratory (CSR), which occurs in heart failure.
CSR is a cycle of breathing, deep, sometimes rapid breathing.
Central Sleep Apnea and Cheyne-Stokes heart failure are 30-50% undetermined and are known as CSA-CSR.
Mixed Sleep Apnea
This mixture of CSA and OSA is an obtuse.
Your doctor can help you further if needed.
If you are worried about your sleep apnea, consult your doctor.
Opioid = Chemical substances that act like morphine in the body. Its main use is analgesia. These agents act by binding to opioid receptors in the central nervous system and the gastrointestinal tract.
Sleep test, or polysomnography, brainwave during the night's sleep, eye movements, respiratory activities, the amount of oxygen in the blood and muscle activity are examined by measuring.
Devices with intelligent control system and state-of-the-art technology that offer solutions for sleep apnea, snoring and sleep disorders
BPAP ST provides better respiration of the patient and reduces the pressure in the breathing and provides a productive sleep.
AUTO SV adjusts the ideal air pressure automatically to provide optimal treatment during the night.
Home Sleep Test (Polysomnography) gives the patient the opportunity to perform sleep analysis in his / her own bed.
Oxygen Concentrator breathing apparatus with oxygen support of approximately 95%
BPAP ST Avaps provides the patient with better breathing, reducing the pressure on the respiratory and providing an efficient sleep.
Portable and Fixed Oxygen Concentrator Devices is an electronic device that provides oxygen as and when needed.
It is a franchise of leading companies in America and Europe in the world medical sector. Our company has experienced, skilled, primarily in Istanbul to provide the best service with the understanding of the dynamic team is active all across Turkey. Turkey's various provinces in the sleep laboratory, expert sales team and dealers with an outstanding product in a complete manner the user is committed to the goal and the most perfect form of transportation.
Since its founding, it has become a leader and preferred company with successful and expansive marketing strategies, and is in a position to catch up to 99% satisfaction in return. Accordingly, RESMED, RESPIROX, BMC, Weinmann and AIRSTEP, one of the biggest medical companies in the world, continue their franchise with a successful and devoted work. He has made himself the principle of being the first choice every year in the market where he is in.